    Effects of detector sensitivity on image quality in multidetector SPECT

  • Author

    Weber, D.A. ; Ivanovic, M. ; Loncaric, S. ; Shelton, D.K.

  • Author_Institution
    Med. Center, California Univ., Davis, CA, USA
  • Volume
    44
  • Issue
    6
  • fYear
    1997
  • fDate
    12/1/1997 12:00:00 AM
  • Firstpage
    2483
  • Lastpage
    2488
  • Abstract
    The common imaging practice of each detector on a multidetector SPECT imaging system to acquire only a fraction of the total number of projections in a 360° projection set introduces the possibility of imbalances in system response which can cause artifacts and changes in image quality. Here we evaluate the effect of variations in detector sensitivity caused by differences in the position of the photopeak window, window width, and different collimators on reconstructed image quality. Analytical simulations of cardiac phantom geometries and experimental measurements with Data Spectrum´s Cardiac and Deluxe SPECT phantoms on a three detector SPECT imaging system were used in the evaluation. The relative efficiency of one of three detectors was changed over a series of values between 100 and 0%, while the efficiency of the remaining two detectors was maintained at 100%. The results show that decreased activity and geometric distortions occur along directions perpendicular to the projections with altered sensitivity. The degree of distortion and decrease of activity depends on the geometry of the activity distribution and the reduction in sensitivity. The relative count ratios in the regions with decreased activity varied over a range of 1.0 to 0.59 as the detector sensitivity is decreased from 100 to 0% of the full energy window. Variations in detector sensitivity can degrade spatial resolution and uniformity and create artifacts in reconstructed tomographic slices
  • Keywords
    biomedical equipment; cameras; gamma-ray detection; image reconstruction; image resolution; medical image processing; single photon emission computed tomography; 360° projection set; SPECT phantoms; activity; activity distribution geometry; analytical simulations; artifacts; cardiac phantom geometries; collimators; detector sensitivity; distortion; geometric distortions; image quality; multidetector SPECT; photopeak window; projections; reconstructed image quality; reconstructed tomographic slices; relative efficiency; spatial resolution; three detector SPECT imaging system; uniformity; window width; Analytical models; Collimators; Degradation; Detectors; Geometry; Image analysis; Image quality; Image reconstruction; Imaging phantoms; Solid modeling;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.656456
  • Filename
    656456