• DocumentCode
    1304861
  • Title

    Effect of Cable Restoration Fluid on Inhibiting Water Tree Initiation

  • Author

    Shu, Wen ; Boggs, Steven A.

  • Author_Institution
    Electr. Insulation Res. Center, Univ. of Connecticut, Storrs, CT, USA
  • Volume
    26
  • Issue
    1
  • fYear
    2011
  • Firstpage
    97
  • Lastpage
    100
  • Abstract
    Silicone fluid has been applied in cable rejuvenation for decades to “cure” existing water trees. However, whether it inhibits future water tree initiation is not known. An electrical aging test has been carried out at 5 kV/mm (127 V/mil) based on a sample which includes semicon electrodes on both sides of the insulation. Samples were tested untreated, treated prior to the test, and treated at the midpoint of the test (3500 h). The results suggest that treatment reduces water tree initiation by a factor of 25 for bow-tie and 100 for vented water trees for the samples treated prior to aging. In the case of samples treated at the mid-point of the test, both bow-tie and vented water tree density are reduced by an order of magnitude relative to the density present at the time of treatment.
  • Keywords
    ageing; cable insulation; cable testing; trees (electrical); cable restoration fluid; electrical aging test; inhibiting water tree initiation; silicone fluid; Aging; Cable insulation; Curing; Moisture; Power cables; Trees - insulation; Cable rejuvenation; water tree;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/TPWRD.2010.2061241
  • Filename