• DocumentCode
    1307629
  • Title

    Active Power Factor Correction (PFC) Circuit With Resistor-Free Zero-Current Detection

  • Author

    Roh, Yong-Seong ; Moon, Young-Jin ; Gong, Jung-Chul ; Yoo, Changsik

  • Author_Institution
    Integrated Circuits Lab., Hanyang Univ., Seoul, South Korea
  • Volume
    26
  • Issue
    2
  • fYear
    2011
  • Firstpage
    630
  • Lastpage
    637
  • Abstract
    An active power-factor correction (PFC) circuit is presented that employs a newly proposed resistor-free zero-current detection (ZCD). While the conventional ZCD requires either a sensing resistor or auxiliary transformer, the proposed ZCD requires only one OFF-chip capacitor. The active PFC circuit with the proposed resistor-free ZCD has been implemented in a 0.35-μm BCDMOS process and the power factor is improved up to 9% from the one employing the conventional ZCD. The proposed resistor-free ZCD scheme can be applied to any type of switch-mode dc-dc power converter.
  • Keywords
    BIMOS integrated circuits; DC-DC power convertors; power factor correction; switched mode power supplies; BCDMOS process; active power factor correction; auxiliary transformer; off chip capacitor; resistor free zero current detection; sensing resistor; size 0.35 mum; switch mode dc-dc power converter; Critical conduction mode (CRM); discontinuous conduction mode (DCM); power-factor correction (PFC); zero-current detection (ZCD);
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2010.2070080
  • Filename
    5559485