  • Abstract
    Measurements of overhead conductor vibration, caused by Von Karman vortex shedding, were carried out with a new experimental device, developed by the authors, capable of continuous monitoring of acceleration over a wide range of frequency and amplitude. Continuous real-time observations showed the important influence of wind direction and turbulence as well as some divergence in predictions of the Strouhal equation.
  • Keywords
    overhead line conductors; power cables; real-time systems; turbulence; vibration measurement; Strouhal equation; Von Karman vortex shedding; aeolian vibrations; continuous acceleration monitoring; overhead conductor vibration measurements; power-line conductors; real-time observations; wind direction; wind turbulence; Frequency measurement; Power transmission lines; Real time systems; Vibration measurement; Vibrations; Wind speed; Aeolian vibrations; conductor vibration measurement; frequency measurement; transmission lines; wind;