• DocumentCode
    1311109
  • Title

    Volumetric In Vivo Imaging of Microvascular Perfusion Within the Intact Cochlea in Mice Using Ultra-High Sensitive Optical Microangiography

  • Author

    Subhash, Hrebesh M. ; Davila, Viviana ; Sun, Hai ; Nguyen-Huynh, Anh T. ; Shi, Xiaorui ; Nuttall, Alfred L. ; Wang, Ruikang K.

  • Author_Institution
    Sch. of Med., Oregon Health & Sci. Univ., Portland, OR, USA
  • Volume
    30
  • Issue
    2
  • fYear
    2011
  • Firstpage
    224
  • Lastpage
    230
  • Abstract
    Studying the inner ear microvascular dynamics is extremely important to understand the cochlear function and to further advance the diagnosis, prevention, and treatment of many otologic disorders. However, there is currently no effective imaging tool available that is able to access the blood flow within the intact cochlea. In this paper, we report the use of an ultrahigh sensitive optical micro-angiography (UHS-OMAG) imaging system to image 3-D microvascular perfusion within the intact cochlea in living mice. The UHS-OMAG image system used in this study is based on spectral domain optical coherence tomography, which uses a broadband light source centered at 1300 nm with an imaging rate of 47thinspace 000 A-scans/s, capable of acquiring high-resolution B scans at 300 frames/s. The technique is sensitive enough to image very slow blood flow velocities, such as those found in capillary networks. The 3-D imaging acquisition time for a whole cochlea is ~ 4.1 s. We demonstrate that volumetric reconstruction of microvascular flow obtained by UHS-OMAG provides a comprehensive perfusion map of several regions of the cochlea, including the otic capsule, the stria vascularis of the apical and middle turns and the radiating arterioles that emanate from the modiolus.
  • Keywords
    biomedical optical imaging; ear; haemodynamics; image reconstruction; medical disorders; medical image processing; optical tomography; 3D imaging acquisition time; 3D microvascular perfusion; blood flow velocity; broadband light source; cochlear function; ear; intact cochlea; otic capsule; otologic disorders; radiating arterioles; spectral domain optical coherence tomography; stria vascularis; ultrahigh sensitive optical microangiography imaging system; volumetric in vivo imaging; Auditory system; Blood; Blood flow; Image resolution; Imaging; Mice; Three dimensional displays; Biomedical optical imaging; blood flow measurement; optical coherence tomography; optical interferometry; optical microangiography; Algorithms; Angiography; Animals; Cochlea; Image Processing, Computer-Assisted; Interferometry; Mice; Mice, Inbred C57BL; Microvessels; Perfusion Imaging; Tomography, Optical Coherence;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2010.2072934
  • Filename
    5560860