DocumentCode :
1311142
Title :
Effect of Nerve Cuff Electrode Geometry on Onset Response Firing in High-Frequency Nerve Conduction Block
Author :
Ackermann, D. Michael, Jr. ; Bhadra, Niloy ; Foldes, Emily L. ; Wang, Xiao-Feng ; Kilgore, Kevin L.
Author_Institution :
Dept. of Biomed. Eng., Case Western Reserve Univ., Cleveland, OH, USA
Volume :
18
Issue :
6
fYear :
2010
Firstpage :
658
Lastpage :
665
Abstract :
The delivery of high-frequency alternating currents has been shown to produce a focal and reversible conduction block in whole nerve and is a potential therapeutic option for various diseases and disorders involving pathological or undesired neurological activity. However, delivery of high-frequency alternating current to a nerve produces a finite burst of neuronal firing, called the onset response, before the nerve is blocked. Reduction or elimination of the onset response is very important to moving this type of nerve block into clinical applications since the onset response is likely to result in undesired muscle contraction and pain. This paper describes a study of the effect of nerve cuff electrode geometry (specifically, bipolar contact separation distance), and waveform amplitude on the magnitude and duration of the onset response. Electrode geometry and waveform amplitude were both found to affect these measures. The magnitude and duration of the onset response showed a monotonic relationship with bipolar separation distance and amplitude. The duration of the onset response varied by as much as 820% on average for combinations of different electrode geometries and waveform amplitudes. Bipolar electrodes with a contact separation distance of 0.5 mm resulted in the briefest onset response on average. Furthermore, the data presented in this study provide some insight into a biophysical explanation for the onset response. These data suggest that the onset response consists of two different phases: one phase which is responsive to experimental variables such as electrode geometry and waveform amplitude, and one which is not and appears to be inherent to the transition to the blocked state. This study has implications for nerve block electrode and stimulation parameter selection for clinical therapy systems and basic neurophysiology studies.
Keywords :
bioelectric potentials; biomedical electrodes; geometry; neuromuscular stimulation; biophysical explanation; bipolar contact separation distance; bipolar separation distance; clinical applications; clinical therapy systems; high-frequency alternating current; high-frequency alternating currents; high-frequency nerve conduction block; muscle contraction; nerve cuff electrode geometry; neurological activity; neuronal firing; neurophysiology; onset response; onset response firing; stimulation parameter selection; therapeutic option; waveform amplitude; Biological neural networks; Biophysics; Electrodes; Force measurement; Nerve tissues; Neural prosthesis; Neurophysiology; High-frequency alternating current; nerve conduction block; nerve cuff electrode; onset response; peripheral nerve; Animals; Data Interpretation, Statistical; Electric Stimulation; Electrodes; Equipment Design; Models, Neurological; Muscle Contraction; Muscle, Skeletal; Nerve Block; Neural Conduction; Rats; Rats, Sprague-Dawley; Sciatic Nerve;
fLanguage :
English
Journal_Title :
Neural Systems and Rehabilitation Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
1534-4320
Type :
jour
DOI :
10.1109/TNSRE.2010.2071882
Filename :
5560864