DocumentCode
1313986
Title
Test results and analysis of two European full-size conductor samples for ITER
Author
Ciazynski, Daniel ; Duchateau, J.L. ; Schild, T. ; Fuchs, A.M.
Author_Institution
CEA, Centre d´Etudes Nucleaires de Cadarache, France
Volume
10
Issue
1
fYear
2000
fDate
3/1/2000 12:00:00 AM
Firstpage
1058
Lastpage
1061
Abstract
The European Home Team is responsible for the design, the fabrication and the test of the Toroidal Field Model Coil (TFMC) of the International Thermonuclear Experimental Reactor (ITER). Within this task, three full-size samples had to be fabricated by industry and to be tested in the SULTAN facility (Villigen, Switzerland). Each sample is composed of two parallel straight bars of full-size conductor, connected at bottom through a joint. This paper reports on the test results and analysis of the first two samples. We present the results of the critical current measurements performed on each conductor leg, the results of the measurements of the joint DC resistance and of the joint quench temperature, the results of joint loss and conductor loss measured under pulsed magnetic field. The results are analysed through comparisons with predictions given by theoretical models. Conclusions are drawn for the expected performances of the TFMC and of the ITER coils.
Keywords
Tokamak devices; fusion reactor design; superconducting coils; DC resistance; European conductor; ITER coil; International Thermonuclear Experimental Reactor; TFMC; Toroidal Field Model Coil; conductor loss; critical current; joint loss; joint quench temperature; pulsed magnetic field; Coils; Conductors; Current measurement; Electrical resistance measurement; Fabrication; Loss measurement; Magnetic analysis; Magnetic field measurement; Pulse measurements; Testing;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/77.828414
Filename
828414
Link To Document