• DocumentCode
    1314224
  • Title

    AC loss and contact resistance in copper-stabilized Nb/sub 3/Al Rutherford cables with and without a stainless steel core

  • Author

    Sumption, M.D. ; Scanlan, R.M. ; Nijhuis, A. ; Collings, E.W.

  • Author_Institution
    Dept. of Mater. Sci., Ohio State Univ., Columbus, OH, USA
  • Volume
    10
  • Issue
    1
  • fYear
    2000
  • fDate
    3/1/2000 12:00:00 AM
  • Firstpage
    1196
  • Lastpage
    1199
  • Abstract
    Calorimetric measurements of AC loss and hence interstrand contact resistance (ICR), were measured on three samples of Rutherford cable wound with Cu-stabilized jelly-roll type unplated Nb/sub 3/Al strand. One of the cable types was furnished with a thin core of AISI 316L stainless steel and the other two were both uncored but insulated in different ways. The cables were subjected to a room-temperature-applied uniaxial pressure of 12 MPa that was maintained during the reaction heat treatment (RHT), then vacuum impregnated with CTD 101 epoxy, and repressurized to 100 MPa during AC-loss measurement. The measurements were performed at 4.2 K in a sinusoidal field of amplitude 400 mT at frequencies of 1 to 90 MHz (no DC-bias field) that was applied both perpendicular and parallel to the face of the cable (the face-on, FO, and edge-on, EO, directions, respectively). For the cored cable the FO-measured effective ICR (FO-ICR), was 5.27 /spl mu//spl Omega/. Those for the uncored cables were less than 0.08 /spl mu//spl Omega/. As shown previously for NbTi- and Nb/sub 3/Sn-based Rutherford cables, the FO-ICR can be significantly increased by the insertion of a core, although in this case it is still below the range recommended for accelerator-magnet use. Post-measurement dissection of one of the cables showed that the impregnating resin had permeated between the strands and coated the core with a thin, insulating layer excepting for some sintered points of contact. In the uncored cables the strands were coated with resin except for the points of interstrand contact. It is suggested that in the latter case this tendency for partial coating leads to a processing-sensitive FO-ICR.
  • Keywords
    aluminium alloys; calorimetry; contact resistance; copper; heat treatment; impregnated insulation; losses; niobium alloys; stainless steel; superconducting cables; superconducting magnets; type II superconductors; 0.08 muohm; 1 to 90 mHz; 100 MPa; 12 MPa; 20 C; 4.2 K; 400 mT; 5.27 muohm; AC loss; AISI 316L stainless steel; Cu-stabilized jelly-roll type unplated Nb/sub 3/Al strand; Nb/sub 3/Al-Cu; calorimetric measurements; contact resistance; copper-stabilized Nb/sub 3/Al Rutherford cables; cored cable; impregnating resin; interstrand contact resistance; reaction heat treatment; room-temperature-applied uniaxial pressure; sinusoidal field; stainless steel core; superconducting magnet; vacuum impregnated CTD 101 epoxy; Cable insulation; Contact resistance; Electrical resistance measurement; Heat treatment; Loss measurement; Niobium; Pressure measurement; Resins; Steel; Wounds;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/77.828448
  • Filename