DocumentCode :
1315249
Title :
An accurate voice-frequency-level calibrating set for field use
Author :
Cochran, W.T.
Author_Institution :
Bell Telephone Laboratories, Inc., Murray Hill, N. J.
Volume :
81
Issue :
6
fYear :
1963
Firstpage :
600
Lastpage :
604
Abstract :
In order to maintain the accuracy of loss measurements commensurate with the requirements of direct distance dialing (DDD), very accurate test tones are needed. This paper describes a rugged, portable calibrating set used to insure the accuracy of the test tones. A telephone craftsman may use this set to adjust the level of a signal with 0.3% accuracy. A means for analytically determining the accuracy of such a set is given in the Appendix.