DocumentCode :
1315499
Title :
Large Area Silicon Microdosimeter for Dosimetry in High LET Space Radiation Fields: Charge Collection Study
Author :
Livingstone, Jayde ; Prokopovich, Dale A. ; Lerch, Michael L F ; Petasecca, Marco ; Reinhard, Mark I. ; Yasuda, Hiroshi ; Zaider, Marco ; Ziegler, James F. ; Pisacane, Vincent L. ; Dicello, John F. ; Perevertaylo, Vladimir L. ; Rosenfeld, Anatoly B.
Author_Institution :
Centre for Med. Radiat. Phys., Univ. of Wollongong, Wollongong, NSW, Australia
Volume :
59
Issue :
6
fYear :
2012
Firstpage :
3126
Lastpage :
3132
Abstract :
Silicon microdosimeters for the characterisation of mixed radiation fields relevant to the space radiation environment have been under continual development at the Centre for Medical Radiation Physics for over a decade. These devices are useful for the prediction of single event upsets in microelectronics and for radiation protection of spacecraft crew. The latest development in silicon microdosimetry is a family of large-area n-SOI microdosimeters for real-time dosimetry in space radiation environments. The response of n-SOI microdosimeters to 2 MeV H and 5.5 MeV He ions has been studied to investigate their charge collection characteristics. The studies have confirmed 100% yield of functioning cells, but have also revealed a charge sharing effect due to diffusion of charge from events occurring outside the sensitive volume and an enhanced energy response due to the collection of charge created beneath the insulating layer. The use of a veto electrode aims to reduce collection of diffused charge. The effectiveness of the veto electrode has been studied via a coincidence analysis using IBIC. It has been shown that suppression of the shared events allows results in a better defined sensitive volume corresponding to the region under the core electrode where the electric field is strongest.
Keywords :
dosimeters; dosimetry; radiation effects; silicon radiation detectors; Centre for Medical Radiation Physics; charge collection characteristics; charge collection study; core electrode; electric field; high LET space radiation fields; large area silicon microdosimeter; large-area n-SOI microdosimeters; mixed radiation fields; real-time dosimetry; space radiation environment; space radiation environments; spacecraft crew radiation protection; Detectors; Dosimetry; Ions; Real-time systems; Silicon on insulator technology; Space technology; Heavy ion therapy; ion beams; microdosimetry; silicon-on-insulator (SOI); space radiation;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2012.2219069
Filename :
6329464
Link To Document :
بازگشت