DocumentCode
1315552
Title
Water and hydrogen equilibrium for different cable constructions
Author
Griffioen, W.
Author_Institution
PTT Res. Neher Labs., Leidschendom, Netherlands
Volume
26
Issue
15
fYear
1990
fDate
7/19/1990 12:00:00 AM
Firstpage
1122
Lastpage
1123
Abstract
Different cables are discussed with respect to hydrogen pressure. Within a few years a pressure of one bar or more can be reached, when leaks appear in the water-barriers, or when metal armouring is used without fully-tight barriers. More open constructions of armouring wires are suggested as a cheap solution for the latter.
Keywords
cable sheathing; optical cables; optical fibres; armouring wires; cable constructions; fully-tight barriers; hydrogen pressure; metal armouring; open constructions; water-barriers;