• DocumentCode
    1315766
  • Title

    The breakdown mechanism of a mid-plane triggered spark gap trigatron

  • Author

    Tang, Hong ; Scuka, Viktor

  • Author_Institution
    Inst. of High Voltage Res., Uppsala Univ., Sweden
  • Volume
    3
  • Issue
    6
  • fYear
    1996
  • fDate
    12/1/1996 12:00:00 AM
  • Firstpage
    843
  • Lastpage
    848
  • Abstract
    A mid-plane triggered spark gap trigatron prototype with adjustable main gap distance and replaceable trigger electrode was constructed and experimentally investigated. The electric parameter measurements, the luminosity measurements and the streak image converter camera were used to study the breakdown mechanism. Electric field distribution in the gap was calculated for the trigatron static and dynamic conditions. The experimental results and analysis show that the space charge around the trigger electrode plays an important role in the breakdown process. Because of the ultra violet irradiation and the existing discharge channel of the first gap segment breakdown, the second gap segment breakdown is much faster. For a mid-plane triggered spark gap trigatron, the optimization of the electric field distribution under dynamic condition can increase the dynamic triggering range appreciably
  • Keywords
    electric breakdown; gas-discharge tubes; spark gaps; breakdown; discharge channel; electric field distribution; luminosity; mid-plane triggered spark gap trigatron; space charge; streak image converter camera; ultra violet irradiation; Breakdown voltage; Circuits; Delay effects; Electric breakdown; Electric variables measurement; Electrodes; Oil insulation; Prototypes; Sparks; Switches;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/94.556570
  • Filename
    556570