Title :
Per unit length parameters of a multiconductor line with earth return inside a tunnel
Author_Institution :
SIRTI S.p.A., Milan, Italy
fDate :
2/1/2000 12:00:00 AM
Abstract :
This paper describes an algorithm for the calculation of the per unit length parameters of a multiconductor line with earth return inside a tunnel in the quasi-static range. The main application of this work is the characterization of an electrified railway line, located inside a generic tunnel, as a source of electromagnetic interference on structures like telecommunication cables, metallic pipes and ducts
Keywords :
electromagnetic interference; multiconductor transmission lines; power overhead lines; railways; telecommunication cables; underground cables; air-soil interface conductors; buries lines; earth return; electrified railway line; electromagnetic interference; metallic ducts; metallic pipes; multiconductor line; overhead lines; per unit length parameters; quasi-static range; telecommunication cables; tunnel; Admittance; Cables; Conductors; Coupling circuits; Ducts; Earth; Electromagnetic interference; Impedance; Rail transportation; Soil;
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on