DocumentCode
1318697
Title
Dielectric losses in condensers
Volume
42
Issue
2
fYear
1923
Firstpage
182
Lastpage
182
Abstract
A comparative study of the methods which are used in measuring dielectric loss in condensers, especially those having a large value of capacitance is being made by the Bureau of Standards, which has an air condenser with a capacitance of 1/10 of a microfarad which will withstand 3000 volts without any appearance of corona. The losses in other condensers may be compared with this air condenser which has negligible loss by means of bridge methods. This is not only the most accurate and dependable method of measuring dielectric loss but also is one of the simplest when there is available a condenser having known losses.
Keywords
Dielectric loss measurement; Dielectric losses; Lighting; Loss measurement; Wrapping;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Journal of the
Publisher
ieee
ISSN
0360-6449
Type
jour
DOI
10.1109/JoAIEE.1923.6592039
Filename
6592039
Link To Document