• DocumentCode
    1318697
  • Title

    Dielectric losses in condensers

  • Volume
    42
  • Issue
    2
  • fYear
    1923
  • Firstpage
    182
  • Lastpage
    182
  • Abstract
    A comparative study of the methods which are used in measuring dielectric loss in condensers, especially those having a large value of capacitance is being made by the Bureau of Standards, which has an air condenser with a capacitance of 1/10 of a microfarad which will withstand 3000 volts without any appearance of corona. The losses in other condensers may be compared with this air condenser which has negligible loss by means of bridge methods. This is not only the most accurate and dependable method of measuring dielectric loss but also is one of the simplest when there is available a condenser having known losses.
  • Keywords
    Dielectric loss measurement; Dielectric losses; Lighting; Loss measurement; Wrapping;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Journal of the
  • Publisher
    ieee
  • ISSN
    0360-6449
  • Type

    jour

  • DOI
    10.1109/JoAIEE.1923.6592039
  • Filename
    6592039