• DocumentCode
    1318874
  • Title

    Stacked p-FET dosimeter for the STRV-2 MWIR detector

  • Author

    Buehler, Martin ; Holmes-Siedle, Andrew ; Caines, Chris ; Carmichael, Christine ; Martin, Dennis

  • Author_Institution
    Jet Propulsion Lab., California Inst. of Technol., Pasadena, CA, USA
  • Volume
    43
  • Issue
    6
  • fYear
    1996
  • fDate
    12/1/1996 12:00:00 AM
  • Firstpage
    2679
  • Lastpage
    2686
  • Abstract
    A stacked p-FET dosimeter consisting of a RADMON mother chip with three p-FETs and multiplexer and an attached RADFET has been developed for the STRV-2/MWIR detector. Calibration of the dosimeter, using an Am-241 source, indicates that the RADFET is about 20 times more sensitive to radiation than the RADMON. This dosimeter is expected to measure radiation dose from rads to Megarads
  • Keywords
    MOSFET; calibration; dosimeters; radiation monitoring; space vehicle electronics; Am; RADMON mother chip; STRV-2 MWIR detector; calibration; radiation dose measurement; space vehicles; stacked p-FET dosimeter; Extraterrestrial measurements; Infrared detectors; Laboratories; Microelectronics; Multiplexing; Packaging; Propulsion; Radiation detectors; Semiconductor device measurement; Space technology;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.556853
  • Filename
    556853