DocumentCode
1318874
Title
Stacked p-FET dosimeter for the STRV-2 MWIR detector
Author
Buehler, Martin ; Holmes-Siedle, Andrew ; Caines, Chris ; Carmichael, Christine ; Martin, Dennis
Author_Institution
Jet Propulsion Lab., California Inst. of Technol., Pasadena, CA, USA
Volume
43
Issue
6
fYear
1996
fDate
12/1/1996 12:00:00 AM
Firstpage
2679
Lastpage
2686
Abstract
A stacked p-FET dosimeter consisting of a RADMON mother chip with three p-FETs and multiplexer and an attached RADFET has been developed for the STRV-2/MWIR detector. Calibration of the dosimeter, using an Am-241 source, indicates that the RADFET is about 20 times more sensitive to radiation than the RADMON. This dosimeter is expected to measure radiation dose from rads to Megarads
Keywords
MOSFET; calibration; dosimeters; radiation monitoring; space vehicle electronics; Am; RADMON mother chip; STRV-2 MWIR detector; calibration; radiation dose measurement; space vehicles; stacked p-FET dosimeter; Extraterrestrial measurements; Infrared detectors; Laboratories; Microelectronics; Multiplexing; Packaging; Propulsion; Radiation detectors; Semiconductor device measurement; Space technology;