• DocumentCode
    1320070
  • Title

    Non-intrusive efficiency estimation method for energy auditing and management of in-service induction motor using bacterial foraging algorithm

  • Author

    Sakthivel, V.P. ; Bhuvaneswari, R. ; Subramanian, Sivaraman

  • Author_Institution
    Dept. of Electr. Eng., Annamalai Univ., Chidambaram, India
  • Volume
    4
  • Issue
    8
  • fYear
    2010
  • Firstpage
    579
  • Lastpage
    590
  • Abstract
    Accurate efficiency estimation of in-service motor is crucial in industries for energy auditing and management. The method defined in IEEE Standard 112 cannot be used for in-service motors, because it disrupts the production process. This study presents a non-intrusive method for in-service motor efficiency estimation based on the bacterial foraging (BF) algorithm. The proposed method relies on measuring the stator current, stator voltage, input power, stator resistance and rotor speed of the in-service motor. The BF algorithm is used for evaluating the equivalent circuit parameters of the motor instead of using the no-load and locked-rotor tests. The efficiency is then estimated using a modified motor model. The proposed method has been tested on a 5 hp motor directly supplied by the grid and the results are compared with those obtained by particle swarm optimisation method, immune algorithm method, ant colony optimisation method, torque gauge method, equivalent circuit method, slip method, current method and segregated loss method. The results demonstrate that the proposed method can estimate motor efficiencies accurately and speedily. Hence, the method is suitable for conducting energy audits and management of the motor to predict cost savings and payback, to assist decisions concerning the investment of an energy efficient motor and also to integrate in an online monitoring system.
  • Keywords
    energy management systems; equivalent circuits; induction motors; rotors; stators; IEEE Standard 112; bacterial foraging algorithm; efficiency estimation; energy auditing; energy management; equivalent circuit parameters; inservice induction motor; locked-rotor tests; no-load tests; nonintrusive method; online monitoring system; power grid; rotor speed; stator current; stator resistance; stator voltage;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IET
  • Publisher
    iet
  • ISSN
    1751-8660
  • Type

    jour

  • DOI
    10.1049/iet-epa.2009.0313
  • Filename
    5569879