Title :
An Exact Analysis of the Method-One Maintainability Demonstration Plan in MIL-STD-471
Author_Institution :
Institute of Industrial Administration, Union College, Schenectady, N.Y. 12308.
Abstract :
The direct method in sequential analysis is used for an exact analysis of the Method-One maintainability demonstration plan in MIL-STD-471. Method-One is a nonparametric binomial sequential test and consists of three plans: A, B1, B2.
Keywords :
Equations; Helium; Parametric statistics; Probability; Quality control; Reliability engineering; Sampling methods; Sequential analysis; Tellurium; Testing;
Journal_Title :
Reliability, IEEE Transactions on
DOI :
10.1109/TR.1972.5215995