• DocumentCode
    1323280
  • Title

    An improved current injection network for three-phase high-power-factor rectifiers that apply the third harmonic current injection

  • Author

    Pejovic, P. ; Janda, Zarko

  • Author_Institution
    Fac. of Electr. Eng., Belgrade Univ.
  • Volume
    47
  • Issue
    2
  • fYear
    2000
  • fDate
    4/1/2000 12:00:00 AM
  • Firstpage
    497
  • Lastpage
    499
  • Abstract
    A novel current injection network for low-harmonic rectifiers that apply the third harmonic current injection is proposed in this paper. The current injection network requires one inductor, two capacitors, and one 1:1 transformer with a voltampere rating of only 0.16% of the input power. The transformer is introduced to provide complete rejection of harmonic components of the injected currents at even triples of the line frequency, resulting in significant reduction of the input current total harmonic distortion (THD). Dependence of the input current THD on the current injection network Q factor is computed. The THD is shown to be in the range 4%<THD<5.125%. Analytically obtained results are experimentally verified on a 1.5 kW rectifier
  • Keywords
    AC-DC power convertors; harmonic distortion; harmonics suppression; power capacitors; power conversion harmonics; power transformers; rectifying circuits; 1.5 kW; Q factor; THD; capacitors; current injection network improvement; harmonic components rejection; inductors; input current total harmonic distortion; third harmonic current injection; three-phase high-power-factor rectifiers; transformers; Capacitors; Computer networks; Frequency; Harmonic distortion; Inductors; Power conversion harmonics; Power system harmonics; Rectifiers; Resistors; Total harmonic distortion;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/41.836366
  • Filename
    836366