• DocumentCode
    1325843
  • Title

    Flashover of vacuum interfaces with many stages and large transit times

  • Author

    Smith, Ian D.

  • Author_Institution
    Pulse Sci. Inc., San Leandro, CA, USA
  • Volume
    25
  • Issue
    2
  • fYear
    1997
  • fDate
    4/1/1997 12:00:00 AM
  • Firstpage
    293
  • Lastpage
    299
  • Abstract
    Methods are developed to calculate the effective breakdown levels and reliabilities of vacuum interfaces with many stages and (where applicable) large transit times. The method assumes that a breakdown equation like that of Martin describes the flashover of individual stages. The Nike and Saturn tubes are used to illustrate the results. Uncertainties in the single insulator breakdown equation are discussed, as are the implications of experience with Saturn and the two AIRIX injectors
  • Keywords
    flashover; vacuum breakdown; vacuum insulation; AIRIX injectors; Nike tubes; Saturn tubes; breakdown equation; effective breakdown levels; flashover; large transit times; many stages; single insulator breakdown equation; vacuum interfaces; Electric breakdown; Equations; Flashover; Insulation; Probability distribution; Saturn; Signal design; Stress; Uncertainty; Vacuum breakdown;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/27.602502
  • Filename
    602502