DocumentCode :
1325843
Title :
Flashover of vacuum interfaces with many stages and large transit times
Author :
Smith, Ian D.
Author_Institution :
Pulse Sci. Inc., San Leandro, CA, USA
Volume :
25
Issue :
2
fYear :
1997
fDate :
4/1/1997 12:00:00 AM
Firstpage :
293
Lastpage :
299
Abstract :
Methods are developed to calculate the effective breakdown levels and reliabilities of vacuum interfaces with many stages and (where applicable) large transit times. The method assumes that a breakdown equation like that of Martin describes the flashover of individual stages. The Nike and Saturn tubes are used to illustrate the results. Uncertainties in the single insulator breakdown equation are discussed, as are the implications of experience with Saturn and the two AIRIX injectors
Keywords :
flashover; vacuum breakdown; vacuum insulation; AIRIX injectors; Nike tubes; Saturn tubes; breakdown equation; effective breakdown levels; flashover; large transit times; many stages; single insulator breakdown equation; vacuum interfaces; Electric breakdown; Equations; Flashover; Insulation; Probability distribution; Saturn; Signal design; Stress; Uncertainty; Vacuum breakdown;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/27.602502
Filename :
602502