Abstract
This paper proposes a new harmonic current-free AC/DC power conversion system characterized by the integration of a small-rated series active filter, with a large-rated double-series diode rectifier. The DC terminals of the active filter are directly connected in parallel with those of the diode rectifier, thereby forming a common DC bus. The active filter enables the diode rectifier to draw three-phase sinusoidal currents from the utility. In addition, it can provide the supplementary value-added function of regulating the common DC-bus voltage to a limited extent of ±5%, slightly increasing the RMS voltage rating, but not increasing the peak voltage rating. Experimental results obtained from a 5 kW laboratory system verify the practical viability and cost effectiveness of the proposed system
Keywords
AC-DC power convertors; active filters; power filters; rectifying circuits; voltage control; 5 kW; DC terminals; RMS voltage rating; common DC bus; common DC-bus voltage regulation; double-series diode rectifier; harmonic current-free AC/DC power conversion; industrial loads; series active filter; three-phase sinusoidal currents; Active filters; Capacitors; Diodes; Power conversion harmonics; Power harmonic filters; Power system harmonics; Pulse width modulation; Pulse width modulation inverters; Rectifiers; Voltage;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/28.633801
Filename
633801
Link To Document