Title :
Comparison of a Reduced-Order Observer and a Full-Order Observer for Sensorless Synchronous Motor Drives
Author :
Tuovinen, Tommi ; Hinkkanen, Marko ; Harnefors, Lennart ; Luomi, J.
Author_Institution :
Dept. of Electr. Eng., Aalto Univ., Espoo, Finland
Abstract :
Two back-electromotive-force-based position observers are compared for motion-sensorless synchronous motor drives: the reduced-order observer and the adaptive full-order observer. A stabilizing gain is proposed for the adaptive full-order observer, which guarantees the local stability of the closed-loop system, if the motor parameters are known. Equations for the steady-state position error and for the linearized estimation-error dynamics under erroneous parameters are derived, and the robustness of the two observers against parameter errors is analyzed and compared. The observers are experimentally evaluated using a 6.7-kW synchronous reluctance motor drive in low-speed operation and under parameter errors. The gain selection of the reduced-order observer is easier, but the adaptive full-order observer can be made more robust against parameter variations and noise.
Keywords :
observers; reluctance motor drives; adaptive full-order observer; back electromotive force-based position observers; closed-loop system; erroneous parameters; gain selection; linearized estimation-error dynamics; local stability; low-speed operation; motion-sensorless synchronous motor drives; motor parameters; parameter errors; power 6.7 kW; reduced-order observer; stabilizing gain; steady-state position error; synchronous reluctance motor drive; Estimation error; Observers; Rotors; Stability analysis; Stators; Steady-state; Vectors; Observer; parameter uncertainties; permanent-magnet (PM) synchronous motor (PMSM); sensorless; stability conditions; synchronous reluctance motor (SyRM);
Journal_Title :
Industry Applications, IEEE Transactions on
DOI :
10.1109/TIA.2012.2226200