DocumentCode
1327028
Title
Interpretation and classification of PD in a HV cryogenic cable termination
Author
Lupó, G. ; Petrarca, C. ; Egiziano, L. ; Tucci, V. ; Vitelli, M.
Author_Institution
Naples Univ., Italy
Volume
7
Issue
1
fYear
2000
fDate
2/1/2000 12:00:00 AM
Firstpage
71
Lastpage
77
Abstract
A description of the experimental and theoretical investigations, carried out for the realization of a cryogenic cable termination, is presented. Identification and classification of the partial discharge (PD) patterns obtained on an HV vacuum bushing and on two types of cable model insulation was attempted. It is shown how a methodological and proper interpretation of experimental data can provide information on the design of cryogenic devices as well as indications on their optimal operating conditions
Keywords
bushings; electric connectors; insulation testing; partial discharge measurement; pattern classification; power cable insulation; power cable testing; superconducting cables; HV cryogenic cable termination; PD pattern classification; insulation diagnosis; partial discharge measurement; vacuum bushing; Cable insulation; Cryogenics; Dielectric liquids; Dielectrics and electrical insulation; Oil filled cables; Partial discharges; Plastic insulation; Solids; Superconducting cables; Temperature;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/94.839343
Filename
839343