DocumentCode :
1328028
Title :
Emergence of the Positive Column in an Atmospheric Air Discharge
Author :
Lehr, Jane M. ; Wallace, Zachariah R. ; Warne, Larry K. ; Jorgenson, Roy E.
Author_Institution :
Sandia Nat. Labs., Albuquerque, NM, USA
Volume :
39
Issue :
11
fYear :
2011
Firstpage :
2274
Lastpage :
2275
Abstract :
The initial stages of electrical breakdown of atmospheric air have been captured with a fast-framing camera. The peak voltage is 100 kV with a duration of 60 ns and is applied to a 4.6-cm gap. The camera captures the start of the positive column, the initial cathode spot, and the development by ionization waves into a hot channel.
Keywords :
cathodes; discharges (electric); plasma diagnostics; plasma waves; atmospheric air discharge; cathode spot; electrical breakdown; fast-framing camera; hot channel; ionization waves; positive column; time 60 ns; voltage 100 kV; Anodes; Cameras; Cathodes; Discharges; Ionization; Plasmas; Atmospheric air discharge; electrical breakdown; ionization waves;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/TPS.2011.2165086
Filename :
6026256
Link To Document :