• DocumentCode
    1330290
  • Title

    Conditions of Exciting Coils Used in Evaluation of Shielding Factor of Magnetically Shielded Rooms for Uniform Magnetic Field

  • Author

    Odawara, Shunya ; Muramatsu, Kazuhiro ; Gao, Yuan ; Komori, S. ; Yamazaki, Kinya ; Shinnoh, Toshifumi ; Yamaguchi, Toru ; Sakakibara, M. ; Shimokawa, M.

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Saga Univ., Saga, Japan
  • Volume
    47
  • Issue
    10
  • fYear
    2011
  • Firstpage
    4274
  • Lastpage
    4277
  • Abstract
    To shield the environmental magnetic noises, magnetically shielded rooms (MSRs) are used for biomagnetic measurements, etc. The sources of environmental noises are far away from the MSR, in such a way that almost uniform magnetic field is applied to the MSR. To evaluate the shielding factor SFo for the uniform magnetic field in a construction site, the magnetic noises are applied by coils. However, SFs depend on the size and position of the coils, so a standardization of the method for accurately evaluating SFo using coils is being discussed in the Japan Electronics and Information Technology Industries Association (JEITA). In JEITA, we have already proposed and verified the method of estimating SFo´s by smaller coils placed near MSRs in the low frequency region without eddy current effect. In this paper, the suitable size and position of coils, such that the errors of the SFo´s estimated and directly evaluated are within 10%, on various shapes of MSRs are obtained using 3-D linear magnetostatic field analysis. Moreover, to correct SFs when the magnetic noises are applied to MSRs through a reinforced concrete wall, etc., the effect of wall on the applied magnetic field is also obtained from the experiment. Finally, the suitable coil conditions and the correction method are verified by the experiment using an actual double-layered MSR.
  • Keywords
    coils; magnetic fields; magnetic noise; magnetic shielding; reinforced concrete; walls; 3D linear magnetostatic field analysis; actual double-layered MSR; environmental magnetic noise; exciting coils; magnetically shielded rooms; reinforced concrete wall; shielding factor; Coils; Current measurement; Magnetic analysis; Magnetic noise; Magnetic shielding; Magnetometers; Magnetostatics; Exciting coil; magnetic field analysis; magnetically shielded room (MSR); shielding factor (SF); standardization;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2011.2151847
  • Filename
    6027761