Conditions of Exciting Coils Used in Evaluation of Shielding Factor of Magnetically Shielded Rooms for Uniform Magnetic Field
Author
Odawara, Shunya ; Muramatsu, Kazuhiro ; Gao, Yuan ; Komori, S. ; Yamazaki, Kinya ; Shinnoh, Toshifumi ; Yamaguchi, Toru ; Sakakibara, M. ; Shimokawa, M.
Author_Institution
Dept. of Electr. & Electron. Eng., Saga Univ., Saga, Japan
Volume
47
Issue
10
fYear
2011
Firstpage
4274
Lastpage
4277
Abstract
To shield the environmental magnetic noises, magnetically shielded rooms (MSRs) are used for biomagnetic measurements, etc. The sources of environmental noises are far away from the MSR, in such a way that almost uniform magnetic field is applied to the MSR. To evaluate the shielding factor SFo for the uniform magnetic field in a construction site, the magnetic noises are applied by coils. However, SFs depend on the size and position of the coils, so a standardization of the method for accurately evaluating SFo using coils is being discussed in the Japan Electronics and Information Technology Industries Association (JEITA). In JEITA, we have already proposed and verified the method of estimating SFo´s by smaller coils placed near MSRs in the low frequency region without eddy current effect. In this paper, the suitable size and position of coils, such that the errors of the SFo´s estimated and directly evaluated are within 10%, on various shapes of MSRs are obtained using 3-D linear magnetostatic field analysis. Moreover, to correct SFs when the magnetic noises are applied to MSRs through a reinforced concrete wall, etc., the effect of wall on the applied magnetic field is also obtained from the experiment. Finally, the suitable coil conditions and the correction method are verified by the experiment using an actual double-layered MSR.
Keywords
coils; magnetic fields; magnetic noise; magnetic shielding; reinforced concrete; walls; 3D linear magnetostatic field analysis; actual double-layered MSR; environmental magnetic noise; exciting coils; magnetically shielded rooms; reinforced concrete wall; shielding factor; Coils; Current measurement; Magnetic analysis; Magnetic noise; Magnetic shielding; Magnetometers; Magnetostatics; Exciting coil; magnetic field analysis; magnetically shielded room (MSR); shielding factor (SF); standardization;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.2011.2151847
Filename
6027761
Link To Document