    The tissue response to epimysial electrodes for diaphragm pacing in dogs

  • Author

    Schmit, Brian D. ; Mortimer, J. Thomas

  • Author_Institution
    VA Med. Center, Cleveland, OH, USA
  • Volume
    44
  • Issue
    10
  • fYear
    1997
  • Firstpage
    921
  • Lastpage
    930
  • Abstract
    Epimysial electrodes stapled to the abdominal surface of the diaphragm produced a chronic inflammatory response that appeared to be mediated by mechanical stresses placed on the encapsulation tissue by periodic diaphragm contraction. The tissue response surrounding 34 epimysial electrodes implanted in 11 dogs was studied three months post implant. The tissue response was characterized by a capsule having a mean thickness of 1.24 mm between the electrode and the muscle, while having only a very thin capsule on the back, or abdominal side of the electrode. The tissue response between the electrode and the muscle was comprised of two tissue layers: a layer of granulation tissue and a layer of collagen. The granulation tissue layer contained evidence of acute inflammatory processes including the presence of polymorphonuclear leukocytes in 68% of the samples. Granulation layer thickness was inversely correlated with back encapsulation indicating a reduction in granulation tissue for mechanically stabilized electrodes. In addition, encapsulation tissue surrounding the granulation layer was comprised of collagen fibers with an oblique orientation and an extraperitoneal locale suggesting mechanical load transfers between the electrode and the surrounding tissue. As a result, the histological response to epimysial electrodes implanted on the diaphragm suggests that mechanical loading, induced by movement associated with the contraction of adjacent muscle, must be a consideration for devices that employ epimysial electrodes.
  • Keywords
    biocontrol; bioelectric phenomena; biomechanics; electrodes; encapsulation; muscle; neurophysiology; pneumodynamics; prosthetics; abdominal surface; acute inflammatory processes; back encapsulation; chronic inflammatory response; collagen; collagen fibers; diaphragm pacing; dogs; encapsulation tissue; epimysial electrodes; extraperitoneal locale; granulation tissue; histological response; mechanical load transfers; mechanical stresses; mechanically stabilized electrodes; muscle; periodic diaphragm contraction; polymorphonuclear leukocytes; tissue response; two tissue layers; Abdomen; Biomedical electrodes; Biomedical engineering; Dogs; Encapsulation; Implants; Laparoscopes; Muscles; Prosthetics; Surgery; Animals; Diaphragm; Dogs; Electric Stimulation Therapy; Electrodes, Implanted; Equipment Design; Evaluation Studies as Topic; Time Factors;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.634644
  • Filename
    634644