Title : 
Influence of a quasi-static magnetic field on quartz crystal resonators
         
        
            Author : 
Li, Hui ; Chen, Xiangdong
         
        
            Author_Institution : 
Sch. of Inf. Sci. & Technol., Southwest Jiaotong Univ., Chengdu, China
         
        
        
        
        
            fDate : 
9/1/2010 12:00:00 AM
         
        
        
        
            Abstract : 
We experimentally study frequency shifts in quartz crystal resonators (QCRs) under quasi-static magnetic fields. It is found that the frequency shifts of the QCR are mainly caused by the magnetomechanical response of the holders of the resonator and the related stresses in the resonator. Understanding and prediction of this effect may be useful for reducing resonator frequency shifts or quasi-static electric/ magnetic field sensing.
         
        
            Keywords : 
crystal resonators; magnetomechanical effects; QCR; frequency shifts; magnetomechanical response; quartz crystal resonators; quasistatic magnetic fields; resonator frequency; Crystals; Electric fields; Electrodes; Magnetic fields; Magnetomechanical effects; Resonant frequency; Sensitivity;
         
        
        
            Journal_Title : 
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
         
        
        
        
        
            DOI : 
10.1109/TUFFC.2010.1657