Abstract :
A simplified design calculation for common-mode chokes for reducing motor ground currents provides insight on the effects of various parameters and allows easy design. Key simplifying assumptions are that the voltage rise time is short compared to the ring period and that the damping is small. Example designs for machines up to 450-mm frame size show how effective ground-current reduction is possible with small inexpensive single-turn chokes.
Keywords :
inductors; invertors; motor drives; common-mode chokes; damping; inverter drives; motor ground current reduction; simplified design calculation; single-turn chokes; voltage rise time; Inductors; Integrated circuit modeling; Permeability; Variable speed drives; Voltage control; CM voltage; Common-mode (CM) current; converter–machine interactions; inductor design; variable-speed drives;