DocumentCode :
1336933
Title :
Inductive detection and concentration measurement of nano sized zero valent iron in the subsurface
Author :
Buchau, A. ; Rucker, W.M. ; de Boer, C.V. ; Klaas, N.
Author_Institution :
Inst. fur Theor. der Elektrotechnik, Univ. Stuttgart, Stuttgart, Germany
Volume :
4
Issue :
6
fYear :
2010
fDate :
11/1/2010 12:00:00 AM
Firstpage :
289
Lastpage :
297
Abstract :
Nano sized zero valent iron (nZVI) can be used for the in-situ remediation of ground water contaminations by halogenated hydrocarbons or other contaminants. A novel approach is presented to detect nZVI and measure the concentration of nZVI in-situ during the remediation process. The presented inductive measurement system makes use of the magnetic material properties of nZVI. A specified magnetic field is generated locally in the aquifer and the magnetic flux density, which depends on susceptibility, is measured. Since the total susceptibility is very small, highly accurate measurements are necessary. Here, accuracy along with sensitivity is significantly improved by post-processing the measured data. Numerical simulations of magnetic fields and 3D visualisation techniques have been applied for development of the measurement technique. Finally, an experiment has been performed to verify the presented measurement method.
Keywords :
inductance measurement; iron; magnetic flux; magnetic materials; numerical analysis; wastewater treatment; 3D visualisation techniques; data postprocessing; ground water contamination; halogenated hydrocarbons; in-situ remediation; inductive detection; inductive measurement system; magnetic field; magnetic flux density; nZVI concentration measurement; nZVI detection; nZVI magnetic material properties; nanosized zero valent iron; numerical simulations; subsurface; susceptibility;
fLanguage :
English
Journal_Title :
Science, Measurement & Technology, IET
Publisher :
iet
ISSN :
1751-8822
Type :
jour
DOI :
10.1049/iet-smt.2009.0116