Title :
Micromachined ultrasonic capacitance transducers for immersion applications
Author :
Bashford, Andrew G. ; Schindel, David W. ; Hutchins, David A.
Author_Institution :
Dept. of Eng., Warwick Univ., Coventry, UK
fDate :
3/1/1998 12:00:00 AM
Abstract :
Investigations into the characteristics of water-coupled ultrasonic capacitance transducers have been undertaken for a range of transducer configurations. The radiated fields have been scanned in water using a miniature hydrophone detector, and the results compared to theory based on a plane piston approach. Micromachined backplates in conjunction with thin Mylar and mica membranes have been investigated, together with aperture modifications such as an annulus and Fresnel zone plate. The measured results agree well with theory, thus demonstrating that wideband predictable performance (>8 MHz) is obtainable with such transducers. Additionally, pulse-echo C-scans of a Plexiglas plate containing an artificial defect have been undertaken with the capacitance transducer, in order to demonstrate that the capacitance transducer has sufficient sensitivity to allow routine nondestructive testing within immersion applications.
Keywords :
capacitance measurement; micromachining; ultrasonic materials testing; ultrasonic transducers; underwater sound; 8 MHz; Fresnel zone plate; Mylar membrane; Plexiglas plate; annulus; aperture; artificial defect; immersion application; mica membrane; micromachined backplate; miniature hydrophone detector; nondestructive testing; plane piston; pulse-echo C-scan; radiated field; water-coupled ultrasonic capacitance transducer; Apertures; Biomembranes; Capacitance; Detectors; Fresnel reflection; Nondestructive testing; Pistons; Sonar equipment; Ultrasonic transducers; Wideband;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on