DocumentCode
1337484
Title
High-power calibration and measurement method for bio-electromagnetic study
Author
Liu, Xindong ; Chen, H.-J. ; Chen, Xia ; Wen, Di ; Parini, Clive
Author_Institution
Beijing University of Posts and Telecommunications,People??s Republic of China
Volume
6
Issue
6
fYear
2012
fDate
11/1/2012 12:00:00 AM
Firstpage
420
Lastpage
426
Abstract
A novel method for high-power calibration/measurement is presented in this work. This method employs a coupler and a dipole antenna to achieve high-power measurement. The coupler serves as a low-power sensor, whereas the dipole antenna is responsible for the high-power measurement. This method successfully calibrated a 600 W 13.56 MHz radio frequency generator and is potentially useful for even higher power measurement, as well as for hazardous high-intensity electromagnetic environment measurement, avoiding the use of expensive high-power metres.
fLanguage
English
Journal_Title
Science, Measurement & Technology, IET
Publisher
iet
ISSN
1751-8822
Type
jour
DOI
10.1049/iet-smt.2011.0187
Filename
6356015
Link To Document