• DocumentCode
    1337660
  • Title

    Calculable coaxial resistors for precision measurements

  • Author

    Elmquist, Randolph E.

  • Author_Institution
    Electr. Div., Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
  • Volume
    49
  • Issue
    2
  • fYear
    2000
  • fDate
    4/1/2000 12:00:00 AM
  • Firstpage
    210
  • Lastpage
    215
  • Abstract
    Coaxial straight-wire resistors have been constructed with the purpose of improving comparisons between resistors, capacitors, and inductors in the audio-frequency range. The design is based on the principle that a coaxial line with a cylindrical shield can be described by relatively simple equations for the real and imaginary parts of the impedance. The resistors, with values at and above 100 Ω will be used as transfer standards for characterization of the frequency dependence of standard resistors and of the quantum Hall resistance in the audio frequency range
  • Keywords
    electric resistance measurement; quantum Hall effect; resistors; skin effect; transfer standards; 100 ohm; AC reference standards; Evanohm wire; audio-frequency range; calculable coaxial resistors; coaxial straight-wire resistors; cylindrical shield; frequency dependence; impedance measurement; precision measurements; quantum Hall resistance; skin effect; standard resistors; transfer standards; Bridge circuits; Capacitors; Coaxial components; Electrical resistance measurement; Frequency dependence; Impedance; Laboratories; Measurement standards; NIST; Resistors;