DocumentCode :
1338255
Title :
Aging diagnosis of insulation systems by PD measurements. Extraction of partial discharge features in electrical treeing
Author :
Bozzo, R. ; Gemme, C. ; Guastavino, F. ; Cacciari, M. ; Contin, A. ; Montanari, G.C.
Author_Institution :
Genoa Univ., Italy
Volume :
5
Issue :
1
fYear :
1998
fDate :
2/1/1998 12:00:00 AM
Firstpage :
118
Lastpage :
124
Abstract :
The charge height values associated with PD measured during electrical tree inception and growth are processed according to the Weibull distribution. Test arrangements, based on the needle-plane electrode system, consider specimens having either a cavity at the tip or an intimate contact with insulation. It is shown that the Weibull-function parameters have close relation to discharges occurring in cavity and tree channels, and that an indication of inception of electrical trees can be obtained
Keywords :
Weibull distribution; ageing; insulation testing; partial discharges; trees (electrical); Weibull distribution; aging diagnosis; cavity; charge height; electrical treeing; insulation system; needle-plane electrode; partial discharge measurement; Aging; Charge measurement; Current measurement; Electric variables measurement; Electrodes; Insulation testing; Partial discharges; System testing; Trees - insulation; Weibull distribution;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/94.660788
Filename :
660788
Link To Document :