Title :
Space charge behavior in full-size 250 kV DC XLPE cables
Author :
Takeda, Toshinao ; Hozumi, Naohiro ; Suzuki, Hiroshi ; Fujii, Koichiro ; Teras, Kazuki ; Hara, Makoto ; Mutrata, Y. ; Wantanabe, K. ; Yoshida, Manabu
Author_Institution :
Central Res. Inst. of Electr. Power Ind., Yokosuka, Japan
fDate :
1/1/1998 12:00:00 AM
Abstract :
The space charge in full size 250 kV HVDC power cables was measured using the pulse-electroacoustic method. Measurements of two types of newly developed DC XLPE cables with 20 mm insulation were taken under a DC voltage of 500 kV with the conductor temperature at room temperature and at 85°C. A qualitative analysis of the space-charge distribution and a quantitative analysis of the electric fields in the vicinity of semicon interfaces were conducted. It was shown that the field in the vicinity of the inner semicon tends to increase by 10-40% when the polarity of the applied voltage was reversed, in the case when the conductor was kept at 85°C. However, the distortion of the electric field was significantly less than that expected in conventional XLPE cables. As the result, the subjected DC cables are considered to have stable DC characteristics from the viewpoint of space charge-behavior
Keywords :
HVDC power transmission; XLPE insulation; electric breakdown; insulation testing; power cable insulation; power cable testing; space charge; 20 mm; 250 kV; 500 kV; 85 C; DC XLPE power cables; DC characteristics; conductor temperature; electric field distortion; pulse-electroacoustic method; space charge behavior measurement; space-charge distribution; Charge measurement; Conductors; Current measurement; HVDC transmission; Power cables; Power measurement; Pulse measurements; Space charge; Temperature; Voltage;
Journal_Title :
Power Delivery, IEEE Transactions on