DocumentCode :
1338840
Title :
Precision Calorimetry for the Accurate Measurement of Losses in Power Electronic Devices
Author :
Weier, Sven ; Shafi, Mohsin A. ; McMahon, Richard
Author_Institution :
Eng. Dept., Univ. of Cambridge, Cambridge, UK
Volume :
46
Issue :
1
fYear :
2010
Firstpage :
278
Lastpage :
284
Abstract :
The direct measurement of losses in power electronic systems is possible through the use of a calorimeter. An improved and fully automated version of a double-jacketed closed-type calorimeter is described in this paper. The accuracy of the calorimeter has been confirmed by calibration tests and is better than 0.1 W in 25 W. The losses in mobile (cell phone) chargers and the ballasts of compact fluorescent lamps have been measured in this calorimeter and are compared to those obtained from conventional measurement methods.
Keywords :
calorimeters; calorimetry; fluorescent lamps; heat losses; lamp accessories; loss measurement; power electronics; ballasts; compact fluorescent lamps; double-jacketed closed-type calorimeter; losses measurement; mobile chargers; power electronic devices; precision calorimetry; Calorimeter; compact fluorescent lamp (CFL); component; loss measurement; mobile charger;
fLanguage :
English