DocumentCode :
1340282
Title :
Relativistic magnetron development for use in a lightweight, repetitively pulsed, portable HPM transmitter
Author :
Spang, S.T. ; Anderson, D.E. ; Busby, K.O. ; Claborn, K.D. ; Manning, S.P. ; Milakovic, A.K. ; Prochazka, J.J. ; Rexroad ; Scannell, E.P. ; Seybold, T.K. ; Williams, R.J., Jr. ; Woodyard, D.A.
Author_Institution :
AAI Corp., Hunt Valley, MD, USA
Volume :
18
Issue :
3
fYear :
1990
fDate :
6/1/1990 12:00:00 AM
Firstpage :
586
Lastpage :
593
Abstract :
The design and development of a relativistic magnetron for use on a portable, repetitively pulsed high-power magnetron (HPM) transmitter is described. Operation of the magnetron at peak power levels of 700 MW, efficiencies of 15%, pulse widths up to 50 ns, output energies of 15 J, and repetition rates of 2 Hz is described. Frequency variation of the magnetron by varying the cathode radius is described, and frequency change during the magnetron pulse is analyzed. Practical system design considerations such as integration, lifetime, reliability, and reproducibility are discussed
Keywords :
magnetrons; relativistic electron beam tubes; cathode radius; high power magnetron; integration; lifetime; portable HPM transmitter; relativistic magnetron; reliability; reproducibility; Cathodes; Circuit testing; Cooling; Frequency; Plasma applications; Power generation; Pulse generation; Pulse power systems; Transmitters; Voltage;
fLanguage :
English
Journal_Title :
Plasma Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-3813
Type :
jour
DOI :
10.1109/27.55931
Filename :