• DocumentCode
    1340282
  • Title

    Relativistic magnetron development for use in a lightweight, repetitively pulsed, portable HPM transmitter

  • Author

    Spang, S.T. ; Anderson, D.E. ; Busby, K.O. ; Claborn, K.D. ; Manning, S.P. ; Milakovic, A.K. ; Prochazka, J.J. ; Rexroad ; Scannell, E.P. ; Seybold, T.K. ; Williams, R.J., Jr. ; Woodyard, D.A.

  • Author_Institution
    AAI Corp., Hunt Valley, MD, USA
  • Volume
    18
  • Issue
    3
  • fYear
    1990
  • fDate
    6/1/1990 12:00:00 AM
  • Firstpage
    586
  • Lastpage
    593
  • Abstract
    The design and development of a relativistic magnetron for use on a portable, repetitively pulsed high-power magnetron (HPM) transmitter is described. Operation of the magnetron at peak power levels of 700 MW, efficiencies of 15%, pulse widths up to 50 ns, output energies of 15 J, and repetition rates of 2 Hz is described. Frequency variation of the magnetron by varying the cathode radius is described, and frequency change during the magnetron pulse is analyzed. Practical system design considerations such as integration, lifetime, reliability, and reproducibility are discussed
  • Keywords
    magnetrons; relativistic electron beam tubes; cathode radius; high power magnetron; integration; lifetime; portable HPM transmitter; relativistic magnetron; reliability; reproducibility; Cathodes; Circuit testing; Cooling; Frequency; Plasma applications; Power generation; Pulse generation; Pulse power systems; Transmitters; Voltage;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/27.55931
  • Filename
    55931