• DocumentCode
    1340804
  • Title

    A new actigraph for long-term registration of the duration and intensity of tremor and movement

  • Author

    Van Someren, Eus J W ; Vonk, Ben F M ; Thijssen, Wim A. ; Speelman, Johannes D. ; Schuurman, Peter R. ; Mirmiran, Majid ; Swaab, Dick F.

  • Author_Institution
    Graduate Sch.of Neurosci., Netherlands Inst. for Brain Res., Amsterdam, Netherlands
  • Volume
    45
  • Issue
    3
  • fYear
    1998
  • fDate
    3/1/1998 12:00:00 AM
  • Firstpage
    386
  • Lastpage
    395
  • Abstract
    Actigraphy, the long-term measurement of human movement with a small solid state recorder, is gaining acceptance as a useful method in many research fields. Currently available actigraphs assess or estimate the movement duration per time interval. However, the output gives no information on movement type or intensity, and cannot be used in subjects suffering from tremor. The present paper describes a new type of actigraph, that has been developed primarily for the long-term evaluation of motor symptoms in Parkinson patients. The device is the first to discriminate tremor from other movements and to assess both duration and intensity of the two types of movement. It is based on a Motorola 68HC805B6 microcontroller and contains: an accelerometer, programmable gain stages, programmable low- and highpass filters, a programmable level comparator, a peak detector, interface circuits, a real time clock, data storage, and control circuitry. The micro-controller performs a period amplitude sequence analysis (PASA) on the conditioned accelerometer signal, and stores four output variables (tremor duration, tremor amplitude, movement duration, and movement amplitude) at the end of programmable time intervals. The analysis of fluctuations in the motor symptoms of, e.g., Parkinson patients using this actigraph can be of great help in the pharmacological management of symptoms.
  • Keywords
    accelerometers; biomechanics; biomedical equipment; biomedical measurement; computerised monitoring; mechanical variables measurement; medical computing; microcontrollers; patient monitoring; Motorola 68HC805B6 microcontroller; Parkinson patients; actigraph; control circuitry; data storage; human movement; interface circuits; long-term registration; motor symptoms evaluation; movement duration; movement intensity; peak detector; pharmacological management; programmable filters; programmable gain stages; programmable level comparator; real time clock; small solid state recorder; Accelerometers; Anthropometry; Clocks; Detectors; Filters; Gain measurement; Memory; Microcontrollers; Motion measurement; Solid state circuits; Aged; Diagnosis, Differential; Electrophysiology; Equipment Design; Humans; Middle Aged; Monitoring, Physiologic; Movement Disorders; Neurology; Parkinson Disease; Sensitivity and Specificity; Signal Processing, Computer-Assisted; Software Design; Tremor; User-Computer Interface; Wrist;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/10.661163
  • Filename
    661163