DocumentCode
1341448
Title
A New Criterion for the Quantification of Broken Rotor Bars in Induction Motors
Author
Xu, Boqiang ; Sun, Liling ; Ren, Hui
Author_Institution
Sch. of Electr. Eng., North China Electr. Power Univ., Baoding, China
Volume
25
Issue
1
fYear
2010
fDate
3/1/2010 12:00:00 AM
Firstpage
100
Lastpage
106
Abstract
This paper addresses itself to evaluate quantitatively the severity of broken rotor bar (BRB) fault, i.e., the number of BRBs in induction motors. Sideband components are induced in stator current if BRB fault is present and commonly used for diagnosis purposes. Filippetti criterion has been proposed and developed in the literature to quantify the severity of BRB fault by using sideband components, however, with unsatisfactory universality/accuracy. This paper briefly analyzes Filippetti criterion, and mathematically derives a new criterion for the quantification of BRBs, based on the electromagnetic mechanism of sideband components. Comparing to Filippetti criterion, the universality and accuracy of the new criterion are both improved. Moreover, the new criterion includes the influence from the interbar currents associated with BRB fault. The related experiment on a 3-kW, 380-V, 50-Hz induction motor has been conducted, and results show the superiority of the new criterion over Filippetti criterion.
Keywords
fault diagnosis; induction motors; rotors; BRB fault; Filippetti criterion; broken rotor bar quantification; electromagnetic mechanism; frequency 50 Hz; induction motors; interbar currents; mathematical derivation; power 3 kW; sideband components; stator current; voltage 380 V; Broken rotor bar (BRB); criterion; diagnosis; induction motor; quantification; severity;
fLanguage
English
Journal_Title
Energy Conversion, IEEE Transactions on
Publisher
ieee
ISSN
0885-8969
Type
jour
DOI
10.1109/TEC.2009.2032626
Filename
5340658
Link To Document