• DocumentCode
    1344957
  • Title

    Negative impulse flashover along cylindrical insulating surfaces bridging a short rod-plane gap under variable humidity

  • Author

    Lazaridis, L.A. ; Mikropoulos, P.N.

  • Author_Institution
    Sch. of Electr. & Comput. Eng., Aristotle Univ. of Thessaloniki, Thessaloniki, Greece
  • Volume
    17
  • Issue
    5
  • fYear
    2010
  • fDate
    10/1/2010 12:00:00 AM
  • Firstpage
    1585
  • Lastpage
    1591
  • Abstract
    Negative impulse flashover along insulating surfaces bridging a short rod-plane gap is investigated under variable humidity. The specimens, cylindrical in shape and with a smooth surface, were made of PTFE, silicone-rubber, nylon and glazed porcelain and were bridging the gap, which was stressed by standard lightning and switching impulse voltages. Breakdown probability distributions were obtained and the breakdown voltage and time to breakdown were measured. The gap was overstressed by applying voltages higher than that causing 100% breakdown so as to study the effects of the applied peak voltage on breakdown characteristics. When breakdown occurs over an insulating surface the breakdown voltage is significantly lower compared to that obtained for air alone, especially at lower breakdown probabilities and under switching impulse voltages. It is also lower for lightning than switching impulse voltages, this being less marked with increasing material permittivity. Breakdown is closely related to negative corona growth. The effect of absolute humidity on breakdown voltage is minimal. The IEC atmospheric conditions correction procedure yields satisfactory results when breakdown occurs both in air alone and along an insulating surface.
  • Keywords
    air gaps; corona; electric breakdown; flashover; insulating materials; statistical distributions; PTFE insulation; air gap; corona; cylindrical insulating surfaces; electrical breakdown probability distributions; material permittivity; negative impulse flashover; nylon insulation; short rod-plane gap; silicone rubber insulation; switching impulse voltages; Breakdown voltage; Corona; Humidity; Lightning; Surface discharges; Switches; Electric breakdown, corona, insulators, surface discharges;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2010.5595561
  • Filename
    5595561