Title :
Maximum overvoltage on aircraft A-C generators after sudden removal of load
Author_Institution :
Westinghouse Electric Corporation, Lima, Ohio
Abstract :
When load is suddenly removed from an a-c generator, the terminal voltage will rise to some maximum value. The magnitude of this overvoltage is a function of several factors such as the amount of load removed, power factor of the load, regulator time delay, exciter response, and the pertinent constants of the a-c generator. This paper presents an analytical study of the influence of these factors on the magnitude of the maximum overvoltage.
Keywords :
Aircraft; Equations; Generators; Mathematical model; Reactive power; Transient analysis; Voltage control;
Journal_Title :
American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
DOI :
10.1109/TAI.1956.6367122