DocumentCode :
1346895
Title :
Negative-sequence voltage detection on aircraft A-C electric systems
Author :
Jessee, R. D. ; Boggess, P. F.
Author_Institution :
Westinghouse Electric Corporation, Lima, Ohio
Volume :
75
Issue :
3
fYear :
1956
fDate :
7/1/1956 12:00:00 AM
Firstpage :
171
Lastpage :
175
Abstract :
SHORT circuits or grounds in aircraft electric power systems or in other parts of the electric system cause unbalanced voltages. These voltages may be detected by several means. One method indicated by a study of symmetrical components is the negative-sequence voltage.1 It can be shown that line-to-line and line-to-ground fault detection can be provided by sensing the negative-sequence voltage.
Keywords :
Aircraft; Circuit faults; Equations; Harmonic analysis; Power harmonic filters; Relays; Sensors;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
Publisher :
ieee
ISSN :
0097-2185
Type :
jour
DOI :
10.1109/TAI.1956.6367166