• DocumentCode
    1347528
  • Title

    Instrumentation for experimental reactor kinetic studies

  • Author

    Gardner, Edward L.

  • Author_Institution
    Atomic International Division of North American Aviation, Inc., Canoga Park, Calif.
  • Volume
    79
  • Issue
    4
  • fYear
    1960
  • Firstpage
    384
  • Lastpage
    388
  • Abstract
    Reactor power excursions involving stable periods ranging from a few seconds to 2 ms (milliseconds) have been experimentally investigated in the course of the Kinetic Experiments on Water Boilers (KEWB) program conducted by Atomics International for the U.S. Atomic Energy Commission. Reactivity introduction, power and temperature measurement, and data analysis have imposed some unique requirements in instrumentation and special apparatus.
  • Keywords
    Acceleration; Inductors; Instruments; Pistons; Torque; Toxicology; Valves;