• DocumentCode
    1349201
  • Title

    Quantitative evaluation of two methods of control bilateral stimulated hand grasps in persons with tetraplegia

  • Author

    Scott, Timothy R D ; Heasman, John M. ; Vare, Veronica A. ; Flynn, Ruth Y. ; Gschwind, Claudia R. ; Middleton, James W. ; Rutkowski, Susan B.

  • Author_Institution
    Dept. of Hand & Microsurg., R. North Shore Hosp., St. Leonards, NSW, Australia
  • Volume
    8
  • Issue
    2
  • fYear
    2000
  • fDate
    6/1/2000 12:00:00 AM
  • Firstpage
    259
  • Lastpage
    267
  • Abstract
    Electrical stimulation has been applied to the paralyzed muscles of both hands of two persons with tetraplegia using percutneous acid implantable electrodes. Two separate methods of user control were being investigated. The first monitored the myoelectric signals from the user´s own sternocleidomastoid muscles and the second monitored wrist joint angle. These signals were used as commands to modify the stimulated grasps. The hands were instrumented to detect the degree of hand closure and grip force and the users matched these to specific target parameters using the controller during tracking tasks. Performance in these tracking tasks was measured quantitatively. Wrist control was found to be less sensitive to the direction of hand opening/closing required than the myoelectric control. The user´s performance with the myoelectric control demonstrated sensitivity to the target size and the speed of hand movement in response to the command control. The wrist controller required less training than the myoelectric controller for users to become proficient in its use. Based on these results, the wrist controller and the myoelectric controller both provide successful control of bilateral hand grasp and release. Of the two controllers, the wrist controller is likely to provide the greater ease of use, although it is only available to the population of users with active wrist extension
  • Keywords
    biocontrol; bioelectric phenomena; biomechanics; neuromuscular stimulation; bilateral stimulated hand grasps control methods; grip force; hand closure degree detection; monitored wrist joint angle; myoelectric control; sternocleidomastoid muscles; target size; tetraplegia; tracking tasks; wrist control; Control systems; Electrodes; Force control; Instruments; Monitoring; Muscles; Size control; Spinal cord; Target tracking; Wrist;
  • fLanguage
    English
  • Journal_Title
    Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1063-6528
  • Type

    jour

  • DOI
    10.1109/86.847827
  • Filename
    847827