DocumentCode :
1351629
Title :
Final TerraSAR-X Calibration Results Based on Novel Efficient Methods
Author :
Schwerdt, Marco ; Bräutigam, Benjamin ; Bachmann, Markus ; Döring, Björn ; Schrank, Dirk ; Gonzalez, Jaime Hueso
Author_Institution :
Microwaves & Radar Inst., German Aerosp. Center (DLR), Wessling, Germany
Volume :
48
Issue :
2
fYear :
2010
Firstpage :
677
Lastpage :
689
Abstract :
TerraSAR-X is a satellite mission for scientific and commercial applications operating a highly flexible X-band synthetic aperture radar (SAR) instrument with a multitude of different operation modes. As product quality is of crucial importance, the success or failure of the mission depends essentially on the method of calibrating TerraSAR-X in an efficient way during commissioning the entire system in a restricted time. Only then, product quality and the correct in-orbit operation of the entire SAR system can be ensured. This paper describes the in-orbit calibration method for TerraSAR-X and dedicated activities performed during the commissioning phase as well as final results derived from all calibration procedures.
Keywords :
calibration; remote sensing by radar; spaceborne radar; synthetic aperture radar; TerraSAR-X; absolute radiometric accuracy; active-phased array antenna; commissioning phase; flexible X-band synthetic aperture radar; in-orbit calibration; pixel localization accuracy; satellite mission; Absolute radiometric accuracy; TerraSAR-X; active-phased array antenna; antenna model; calibration; pixel localization accuracy; synthetic aperture radar (SAR);
fLanguage :
English
Journal_Title :
Geoscience and Remote Sensing, IEEE Transactions on
Publisher :
ieee
ISSN :
0196-2892
Type :
jour
DOI :
10.1109/TGRS.2009.2035308
Filename :
5350726
Link To Document :
بازگشت