    Discussion on “direct-current and alternating-current mill motors for auxiliary drives” (Wiley), Pittsburgh, Pa. April 25, 1912. (see proceedings for May, 1912)

  • Volume
    31
  • Issue
    11
  • fYear
    1912
  • Firstpage
    2033
  • Lastpage
    2040
  • Abstract
    Alexander C. Lanier: Mr. Wiley´s paper has brought out the principal demands made upon motors in mill and crane service and my remarks will be limited to direct-current mDtors suitable for such applications. Commutation is always a factor of first importance in the direct-current motor; service conditions met in mill work are much more severe than in the ordinary industrial application. During the operating cycle the load usually varies between wide limits, and momentary peaks may reach three or four times the one hour rated load.
  • Keywords
    Brushes; Coils; Commutation; Fasteners; Heating; Induction motors; Loss measurement;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Proceedings of the
  • Publisher
    ieee
  • ISSN
    0097-2444
  • Type

    jour

  • DOI
    10.1109/PAIEE.1912.6659953
  • Filename