• DocumentCode
    1354090
  • Title

    Comparative Evaluation of Susceptibility to Motion Artifact in Different Wearable Systems for Monitoring Respiratory Rate

  • Author

    Lanata, Antonio ; Scilingo, Enzo Pasquale ; Nardini, Elena ; Loriga, Giannicola ; Paradiso, Rita ; De-Rossi, Danilo

  • Author_Institution
    Interdepartmental Res. Center E. Piaggio, Univ. of Pisa, Pisa, Italy
  • Volume
    14
  • Issue
    2
  • fYear
    2010
  • fDate
    3/1/2010 12:00:00 AM
  • Firstpage
    378
  • Lastpage
    386
  • Abstract
    The purpose of this study is to comparatively evaluate the performance of different wearable systems based on indirect breathing monitoring in terms of susceptibility to motion artifacts. These performances are compared with direct respiratory measurements using a spirometer, which is accurate, reliable, and less sensitive to movement artifacts, but cannot be integrated into truly wearable form. Experiments were carried out on four indirect methods implemented into wearable systems, inductive plethysmography, impedance plethysmography, piezoresistive pneumography, and piezoelectric pneumography, to ascertain the performance of each of them in terms of noise due to movement artifacts, as well as to study the effects of different movements or gestures during each test. A group of volunteers was asked to wear all of the breath monitoring systems simultaneously along with the face mask of the spirometer while carrying out four physical exercises in a gym under controlled conditions. Data are analyzed in the time and frequency domain to estimate the frequency respiration from each wearable system and compare it with those of the spirometer. Results confirmed that all the wearable systems are somehow affected by movement artifacts, but statistical investigation showed that for most of the physical exercises, three out of four, piezoelectric pneumography provided best performance in terms of robustness and reduced susceptibility to movement artifacts.
  • Keywords
    bioelectric phenomena; electric sensing devices; fast Fourier transforms; frequency-domain analysis; patient monitoring; piezoelectric devices; piezoresistive devices; plethysmography; pneumodynamics; respiratory protection; time-domain analysis; breath monitoring systems; face mask; frequency domain; frequency respiration; gestures; impedance plethysmography; indirect breathing monitoring; inductive plethysmography; motion artifact susceptibility; movements; physical exercises; piezoelectric pneumography; piezoresistive pneumography; respiratory rate monitoring; spirometer; statistical investigation; time domain; wearable systems; Plethysmography; pneumography; respiratory rate monitoring; spirometer; wearable systems; Adult; Artifacts; Clothing; Female; Humans; Male; Monitoring, Ambulatory; Motor Activity; Plethysmography; Respiratory Rate; Signal Processing, Computer-Assisted; Spirometry; Statistics, Nonparametric;
  • fLanguage
    English
  • Journal_Title
    Information Technology in Biomedicine, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1089-7771
  • Type

    jour

  • DOI
    10.1109/TITB.2009.2037614
  • Filename
    5352286