• DocumentCode
    1354101
  • Title

    Enhancement of Fiber Orientation Distribution Reconstruction in Diffusion-Weighted Imaging by Single Channel Blind Source Separation

  • Author

    Jing, Min ; McGinnity, T. Martin ; Coleman, Sonya ; Zhang, Huaizhong ; Fuchs, Armin ; Kelso, J. A Scott

  • Author_Institution
    Intell. Syst. Res. Centre, Univ. of Ulster, Derry, UK
  • Volume
    59
  • Issue
    2
  • fYear
    2012
  • Firstpage
    363
  • Lastpage
    373
  • Abstract
    In diffusion-weighted imaging (DWI), reliable fiber tracking results rely on the accurate reconstruction of the fiber orientation distribution function (fODF) in each individual voxel. For high angular resolution diffusion imaging (HARDI), deconvolution-based approaches can reconstruct the complex fODF and have advantages in terms of computational efficiency and no need to estimate the number of distinct fiber populations. However, HARDI-based methods usually require relatively high b-values and a large number of gradient directions to produce good results. Such requirements are not always easy to meet in common clinical studies due to limitations in MRI facilities. Moreover, most of these approaches are sensitive to noise. In this study, we propose a new framework to enhance the performance of the spherical deconvolution (SD) approach in low angular resolution DWI by employing a single channel blind source separation (BSS) technique to decompose the fODF initially estimated by SD such that the desired fODF can be extracted from the noisy background. The results based on numerical simulations and two phantom datasets demonstrate that the proposed method achieves better performance than SD in terms of robustness to noise and variation in b-values. In addition, the results show that the proposed method has the potential to be applied to low angular resolution DWI which is commonly used in clinical studies.
  • Keywords
    biodiffusion; biomedical MRI; deconvolution; image enhancement; image reconstruction; medical image processing; phantoms; source separation; MRI; angular resolution diffusion imaging; deconvolution-based approaches; diffusion-weighted imaging; enhance performance; fiber orientation distribution function; fiber orientation distribution reconstruction enhancement; low angular resolution DWI; noisy background; numerical simulation; phantom datasets; relatively high b-values; reliable fiber tracking; single channel blind source separation technique; spherical deconvolution approach; Brain modeling; Deconvolution; Image reconstruction; Imaging; Noise; Numerical simulation; Signal resolution; Diffusion-weighted imaging; fODF reconstruction; single channel blind source separation; spherical deconvolution; Algorithms; Brain; Computer Simulation; Databases, Factual; Diffusion Magnetic Resonance Imaging; Humans; Image Processing, Computer-Assisted; Models, Statistical; Nerve Fibers; Phantoms, Imaging;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2011.2172793
  • Filename
    6054017