• DocumentCode
    1356533
  • Title

    Long term wet ageing of extruded dielectric cables

  • Author

    Banks, V.A.A. ; Noyes, R.P. ; Vail, J. ; Hampton, R.N.

  • Author_Institution
    BICC General, Wrexham, UK
  • Volume
    14
  • Issue
    3
  • fYear
    2000
  • fDate
    6/1/2000 12:00:00 AM
  • Firstpage
    121
  • Lastpage
    126
  • Abstract
    Experience outside the UK with service failures of wet MV extruded dielectric cables has led to extensive worldwide studies. This article describes work carried out at BICCGeneral UK since the 1970s and reviews the results of long-term tests (up to ten years) under working conditions on cables manufactured in the 1970s and 1980s. The results are compared with data from two-year UNIPEDE tests at 2/spl middot/5U/sub o/ on 1990s cable and demonstrate the good service performance obtained with these cables. European and North American service failure data, obtained from the literature, is then used with the service survival data on these cables to estimate their expected lifetime.
  • Keywords
    power cable insulation; BICCGeneral UK; European service failure data; North American service failure data; UNIPEDE tests; expected cable lifetime estimation; extruded dielectric cables; long term wet ageing; long-term tests; service failures; service performance; wet MV extruded dielectric cables; working conditions;
  • fLanguage
    English
  • Journal_Title
    Power Engineering Journal
  • Publisher
    iet
  • ISSN
    0950-3366
  • Type

    jour

  • DOI
    10.1049/pe:20000305
  • Filename
    850804