In Vivo Gas Body Efficacy for Glomerular Capillary Hemorrhage Induced by Diagnostic Ultrasound in Rats
Author :
Miller, Douglas L. ; Dou, Chunyan ; Wiggins, Roger C.
Author_Institution :
Dept. of Radiol., Univ. of Michigan Health Syst., Ann Arbor, MI, USA
Volume :
57
Issue :
1
fYear :
2010
Firstpage :
167
Lastpage :
174
Abstract :
Glomerular capillary hemorrhage (GCH) in rat kidney provided a model for assessing in vivo gas body efficacy in diagnostic or therapeutic applications of ultrasound. Two diagnostic ultrasound machines were utilized: one monitored the harmonic B-mode contrast enhancement of the left kidney and the other exposed the right kidney for GCH production. Definity contrast agent was infused at 1, 2, 5, or 10 ??L/(kg??min) and infusion durations were 30, 60, 120, or 300 s. Exposure of the right kidney was at a peak rarefactional pressure amplitude of 2.3 MPa at 1.5 MHz. The circulating dose was estimated with a simple model of agent dilution and gas body loss. For 300 s infusion at 5 ??L/(kg??min), the left kidney image brightness increased to a plateau with an estimated 6.4 ?? 1.3 ??L/kg circulating dose with no GCH in histological sections. Exposure of the right kidney with a 1-s image interval reduced the estimated circulating dose to 1.3 ?? 0.3 ?? L/kg and induced 68.4% GCH. Dose and duration increases gave rapidly diminishing treatment effectiveness per gas body. The effective in vivo agent dose in rats can be reduced greatly due to high gas body destruction in the small animal, complicating predictions for similar conditions of human treatment.
Keywords :
bioacoustics; biological effects of acoustic radiation; biomedical ultrasonics; kidney; diagnostic ultrasound; gas body efficacy; glomerular capillary hemorrhage; harmonic B-mode contrast enhancement; image brightness; rat kidney; time 120 s; time 30 s; time 300 s; time 60 s; Animals; Biomedical imaging; Brightness; Condition monitoring; Hemorrhaging; Humans; In vivo; Production; Radiology; Rats; Testing; Ultrasonic imaging; Biological effects of acoustic radiation; biomedical imaging; image analysis; medical diagnosis; medical treatment; ultrasound contrast agent; Algorithms; Animals; Contrast Media; Dose-Response Relationship, Drug; Hemorrhage; Kidney Diseases; Kidney Glomerulus; Linear Models; Microbubbles; Rats; Ultrasonography;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2009.2030960
Filename :
5223685
Link To Document :
بازگشت