DocumentCode
1357614
Title
Fuzzy Filtering for Physiological Signal Analysis
Author
Kumar, Mohit ; Weippert, Matthias ; Arndt, Dagmar ; Kreuzfeld, Steffi ; Thurow, Kerstin ; Stoll, Norbert ; Stoll, Regina
Author_Institution
Center for Life Sci. Autom., Rostock, Germany
Volume
18
Issue
1
fYear
2010
Firstpage
208
Lastpage
216
Abstract
This study suggests the use of fuzzy-filtering algorithms to deal with the uncertainties associated to the analysis of physiological signals. The signal characteristics, for a given situation or physiological state, vary for an individual over time and also vary among the individuals with the same state. These random variations are due to the several factors related to the physiological behavior of individuals, which cannot be taken into account in the interpretation of signal characteristics. Our approach is to reduce the effect of random variations on the analysis of signal characteristics via filtering out randomness or uncertainty from the signal using a nonlinear fuzzy filter. A fuzzy-filtering algorithm, which is based on a modification of filtering algorithm of Kumar et al. [M. Kumar, N. Stoll, and R. Stoll, IEEE Trans. Fuzzy Syst., vol. 17, no. 1, pp. 150-166, Feb. 2009], is proposed for an improved performance. The method is illustrated by studying the effect of head-up tilting on the heart-rate signal of 40 healthy subjects.
Keywords
filtering theory; fuzzy set theory; fuzzy systems; medical signal processing; nonlinear filters; physiological models; fuzzy-filtering algorithm; head-up tilting; heart-rate signal; nonlinear fuzzy filter; physiological signal analysis; signal characteristics; Features extraction; fuzzy filtering; head-up tilt (HUT) test; physiological signals;
fLanguage
English
Journal_Title
Fuzzy Systems, IEEE Transactions on
Publisher
ieee
ISSN
1063-6706
Type
jour
DOI
10.1109/TFUZZ.2009.2038709
Filename
5353713
Link To Document