• DocumentCode
    1358419
  • Title

    Evaluation of Three-Phase Transformerless Photovoltaic Inverter Topologies

  • Author

    Kerekes, Tamas ; Liserre, Marco ; Teodorescu, Remus ; Klumpner, Christian ; Sumner, Mark

  • Author_Institution
    Inst. of Energy Technol., Aalborg Univ., Aalborg, Denmark
  • Volume
    24
  • Issue
    9
  • fYear
    2009
  • Firstpage
    2202
  • Lastpage
    2211
  • Abstract
    This paper analyzes and compares three transformerless photovoltaic inverter topologies for three-phase grid connection with the main focus on the safety issues that result from the lack of galvanic isolation. A common-mode model, valid at frequencies lower than 50 kHz, is adopted to study the leakage current paths. The model is validated by both simulation and experimental results. These will be used to compare the selected topologies, and to explain the influence of system unbalance and the neutral conductor inductance on the leakage current. It will be demonstrated that the later has a crucial influence. Finally, a comparison of the selected topologies is carried out, based on the adopted modulation, connection of the neutral and its inductance, effects of unbalance conditions, component ratings, output voltage levels, and filter size.
  • Keywords
    invertors; photovoltaic power systems; common-mode model; galvanic isolation; three-phase grid connection; three-phase transformerless photovoltaic inverter topologies; Conductors; Frequency; Galvanizing; Inductance; Inverters; Leakage current; Photovoltaic systems; Safety; Solar power generation; Topology; Inverters; leakage currents; pulsewidth-modulated (PWM) inverters;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2009.2020800
  • Filename
    5226551